HEATING ENERGY CALCULATORS AIR CONDITIONING AIR QUALITY
 
   
 
Air Conditioning
13 SEER Air Conditioning Efficiency
Add Central Air Conditioning
Additions & Remodels
Air Filters
Air Handlers
Air Purifiers
Air To Air Exchangers
Central Air Conditioning
Condensers
Controls
Cooling Coils
Dehumidification
Ductless Mini-Split
Ductwork & Distribution
Duct Design and Dynamics
Efficiencies
Electronic Air Cleaner
Energy Conservation
Energy Conservation Calculators
Energy Savers
Fuel Cells
Geothermal Furnace
Heat Gain
Heat Pumps
Hydro-Air
Maintenance Tips
Motorized Dampers
Portable Air Conditioners
Problem Areas
Programmable Thermostats
Refrigeration Cycle
Return System
Self Contained
Solar Cooling
System Design
Troubleshooting Tips
Window Air Conditioner
Wine Cellars
Zoning
 
HEATING
Add On Wood Furnace
Additions & Remodels
Air Filters
Air Purifiers
Air To Air Exchangers
Aquastats
Attic Insulation Calculator
Boilers
Bypass Humidifier
Chimneys & Power Ventors
Controls
Corn Furnaces
Ductless Mini-Split
Ductwork & Distribution
Duct Design and Dynamics
Efficiencies
Electric Furnaces
Electronic Air Cleaner
Energy Conservation
Energy Conservation Calculators
Energy Savers
Forced Warm Air
Fuel Cells
Fuel Cost Calculator
Gas Furnaces
Gas Furnace Ratings
Geothermal Furnace
Heat Loss
Heat Pumps
Humidification
Hydro-Air
Hydronic Heating Systems
Insulation
Maintenance Tips
Motorized Dampers
Oil Burners
Oil Furnaces
Oil Furnace Ratings
Portable Furnace
Problem Areas
Programmable Thermostats
Radiant Heat
Replacements
Return System
Self Contained
Solar Heating
System Design
Thermostat Savings Calculator
Troubleshooting Tips
Waste Oil Furnace
Window Replacement Calculator
Wood Boiler
Wood Furnaces
Zoning
 
Air Conditioning Topics and Tools
 
Condensers
 

The condenser for a heat pump and a central air conditioning system look similar and are constructed of the same basic parts. A cabinet houses the components and is strong enough to protect them during transport and installation. Inside of the cabinet will be a condenser coil, a compressor, a fan, and controls.

The coil is usually made of copper tubing with aluminum fins, but some manufactures use aluminum tubing. Its purpose is to transfer heat as rapidly as possible. Pressure inside the coil can exceed 400 psi., during extremely warm weather conditions. The cleaner it is kept, the better it transfers heat. Rinsing with a garden hose occasionally when the unit is not running will help keep it operating efficiently. After many years of use it may be necessary to put special chemicals on to clean it.

The condenser fan moves air across the coil to increase the transfer of heat. It is critical to the system. Obstructing the flow of air will not only reduce efficiency but can lead to compressor failure. Keep debris and objects away from the coil and fan to allow maximum air flow. Some condenser fan motors have sealed bearings, others need lubrication. Damage to the fan can occur if removed improperly. Have a qualified serviceman handle the lubricating if needed.

The compressor is the engine of the system. It compresses the refrigerant and pumps it to a coil as a hot gas. For air conditioning, it will be cooled at the condenser into a warm liquid and piped to the evaporator coil to expand and cool. For a heat pump, the hot gas will be pumped directly to the evaporator coil to provide heat. Compressors are of two designs; reciprocating and scroll. A reciprocating compressor is similar to an air compressor. An electric motor spins a crankshaft with pistons and connecting rods. Valves open and close to allow the flow of gas in the desired direction. Special lubricants are used.

Since the system is hermetically sealed, the lubricant is permanent and does not get changed. Reciprocating compressors have been in use since the first refrigerators. Scroll compressors use an electric motor to drive them, but the similarity ends here. Its uniqueness is difficult to explain, but it is ingenious. Using two spiral mazes recessed into each other, one attached to a motor drive an d the other allowed to slide freely, compression occurs with rapid movement. After many years of testing and engineering improvements, the scroll compressor is available from some manufacturers as a standard or option in the condenser. It is both efficient and quiet, and improve with age.

If the condenser is used for air conditioning only, controls are minimal. A contactor switches the power on and off. Capacitors are used to start and run the motors. Optional controls are: a brown-out time delay, crankcase heater. Hard start kit, and low ambience control.

 

A brown-out time delay protects the compressor in two ways. If the voltage drops and the motors draw too much current(amperes) it shuts the contactor off. If the control voltage is interrupted momentarily, it shuts the contactor off. When the compressor is running, high pressure exists at the exhaust port. If it is shut down and restarted before the pressure equalizes with the intake port, the motor will not be able to overpower the pressure imbalance and overheat. The time delay will stall the restart for three or four minutes; sufficient time for the pressures to equalize.

The compressor is deigned to compress a gas, not a liquid. A crankcase heater is used to preheat the oil and liquid refrigerant that might have settled in the compressor crankcase. By boiling off any refrigerant, risk of valve damage is avoided.

If rapid restarts are required for the system, a hard start kit can be installed. It consists of a potential relay and a capacitor. It gives the motor an added jolt or boost to help it start under stress.

Mostly used in commercial applications, a low ambience control could be used on a residential system if needed. It senses the liquid line pressure and cycles the condenser fan to keep pressure high enough for the air conditioning to function in cold weather.

If the condenser is part of a heat pump system, the controls get more complex. In addition to the controls already listed, there will be a reversing valve, defrost timer, and possibly an adjustable temperature sensor.

The reversing valve directs the flow of compressed gas to the condenser coil for air conditioning or to the evaporator coil for heating.

When extracting heat from outdoor air, the condenser coil gets very cold and frost will begin to form on it. Too much frost build-up will restrict air flow and reduce effectiveness of the coil. The defrost control switches to air conditioning mode without the condenser fan running. The hot gas running through the coil melts the ice that formed, then shifts back to heating mode.

Some older model heat pumps have an adjustable thermostat in the outdoor control panel. It will limit the low temperature operation of the heat pump to prevent it from running when it is too cold out to extract sufficient heat from the air.

 
 
Energy Conservation Calculators
Attic Insulation Calculator
To calculate energy savings with increased insulation
 
Clean Air Delivery Rate (CADR) Calculator
Estimate the proper size Air Purifier for your room
 
Fuel Comparison
To compare heating costs using various fuels
 
Mini-Split Estimator
Find out the right size mini-split for you
 
Thermostat Set-back
To calculate fuel savings by adjusting your thermostat settings
 
Air Conditioner Efficiency
Calculate energy savings with higher SEER ratings
 
Computer Room Air Conditioner
Size an air conditioner for your computer room
 
Window Air Conditioner Estimator
To size a room air conditioner
 
Window Upgrade
To calculate energy savings with various window replacements
 
Heatload.com
To size an Air Conditioner or Furnace for a house
 
Bypass Humidifier
Approximate your humidifier size requirements
 
Air Exchanger Sizing Calculator
Properly size an Air Exchanger for your home.
 
           
     